In order to verify the seepage characteristic of the levee project in the Xiajiang reservoir area,the method of Water Injection Test(WIT)was used to determine the permeability coefficient.Comparison analysis by field test and laboratory test show that the WIT is a simple and effective method of determination of the levee permeability coefficient,and the test results are good coincidence with the seepage characteristic of the levee project.