This paper focus on analyzing the influence of bearing structure for service radial gate at upper outlets on arch dam under the same construction condition, by doing the finite element analysis to the model of arch dam. The size and distribution range are calculated under the different structural forms. This paper analyzes the stress distribution in different structural forms and provides a reference for the design of the Bearing Structure for Service Radial Gate at upper outlets.