Abstract:Based on the geophysical exploration,hydrogeological survey,drilling hole exploration and pumping test and combined with the regional hydrological and geological data,the geothermal geological conditions and thermal storage occurrence condition in Gantang of Douyun city of Guizhou province are analyzed.And thermal reservoir fluid water resources and geothermal resources are calculated.The quality of geothermal water resources is assessed.